Our PC Multiwall Sheet is made of polycarbonate (PC) resin which is the world’s most versatile materials, with the characteristics of high impact strength, is the perfect coordination with light weight and high strength, and the material itself was transparent as water as clear. It is widely used in stadiums, public buildings, industrial buildings, civil construction, modern greenhouses and interior decoration display, etc., and providing high-quality low-maintenance lighting solution for these occasions.
Transparent
General PC Multiwall Sheet ’s light transmission rate is up to 80%.
Ageing resistance
General PC Multiwall Sheet is UV co-extruded mixed,which can block ultraviolet rays pass through, so have a good weather resistance.
Excellent energy efficiency
General PC Multiwall Sheets are hollow structure, so that the air between the layers are there to gain excellent insulation properties, cool in summer and warm in winter. 10mm General PC Multiwall Sheet heat transfer coefficient K value is 3.1 W/(m2·K).
Light weight
The proportion of General PC Multiwall Sheet is only about 1/15 of normal glass, saving transportation, unloading, installation, and the costs of the support framework.
Easy to install
Easily with conventional tools for on-site cutting, can be cold-formed to form a small radius of curvature of the arc without the need for pre-bending treatment, the minimum bend radius of 175 times to the thickness. For cutting, sawing, drilling does not occur broken, damaged, so very little waste material.
Fire-retardant
General PC Multiwall Sheet’s own ignition is 580 ° C, will be self-extinguishing away from the fire. Combustion does not produce toxic gases, not spreading the fire, according to national standard GB8624-2006 which flame retardant is B level.
Impact resistance
General PC Multiwall Sheet has a good impact resistance, the impact strength is 80 times of the ordinary glass, 14 times to the acrylic sheet of the same thickness.
Simulated hail impact test: In the simulated hail impact test machine to simulate hail impact, will be a diameter of 20mm (weight 4.8g) of nylon balls to 21m / s speed of the launch of the model to observe the extent of damage model and found that glass and acrylic forces have been cracking or breaking, while the General PC Multiwall Sheet is not broken. Real life, a diameter of 20mm hail the ultimate speeds is up to 21m / s.
Sound insulation
General PC Multiwall Sheet’s sound insulation is obvious effects than the same thickness of glass and Acrylic panels for better sound insulation in the international arena, and is the prefer choice material for highway noise barriers. For example: 10mm General PC Multiwall Sheet’s sound insulation is 19dB.
Adapt to the larger temperature difference
General PC Multiwall Sheet does not occur the cold crisp in the -40 ° C and in the 120 ° C without softening, in the harsh environment of its Mechanics, mechanical properties, etc. have no significant changed.
Typical performance indicators
Item | Inspection Standard | Units | Data |
Thickness | mm | 8 | |
UV layer thickness | μm | 50 | |
Structure | 2RS | ||
Minimum bend radius | mm | 1400 | |
Standard width | mm | 2100 | |
Standard length | mm | 5800 | |
Transmittance | |||
Clear TR001 | GB/T 2410-1980 | % | 78 |
Heat transfer coefficient | GB/T 8484-1987 | W/(m2.K) | 3.3 |
Sound reduction value | GB/T 8485-1987 | Db | 17 |
Drop hammer impact test | GB/T 11548 -1989 | m/s | >21 |
Coefficient of thermal expansion | GBT8484-2002 | Mm/m ℃ | 0.067 |
Flame Level | GB 8624-2006 | B-s1.d0.t1 | |
Temperature Range | ℃ | -40~120 |
Item | Inspection Standard | Units | Data |
Thickness | mm | 4 | |
UV layer thickness | μm | 50 | |
Structure | 2RS | ||
Minimum bend radius | mm | 700 | |
Standard width | mm | 2100 | |
Standard length | mm | 5800 | |
Transmittance | |||
Clear TR001 | GB/T 2410-1980 | % | 80 |
Heat transfer coefficient | GB/T 8484-1987 | W/(m2.K) | 3.3 |
Sound reduction value | GB/T 8485-1987 | Db | 17 |
Drop hammer impact test | GB/T 11548 -1989 | m/s | >21 |
Coefficient of thermal expansion | GBT8484-2002 | Mm/m ℃ | 0.067 |
Flame Level | GB 8624-2006 | B-s1.d0.t1 | |
Temperature Range | ℃ | -40~120 |
Standard thickness:4mm, 5mm, 6mm, 8mm , 10mm , 12mm, 14mm, 16mm
Standard width:1220mm(only 4mm、5mm & 6mm thickness), 2100mm
Standard length :6000mm (Other lengths can be customized according to customer request), regular length:5800mm(for 20’ft container),11800mm(for 40’ft container)
Color: Clear, Lake Blue, Grass green, Blue, Opal, Brown
● Commercial building lighting
● Industrial buildings lighting
● Stadium roof and indoor games areas
● Transport infrastructure
● Residential building lighting
● Greenhouse
● Noise Wall
● Building envelope and curtain wall
● Signs board and sale point’s advertising
● Building interiors